блог
Дом /

блог

/

This Embedding Center Cold Plate Doubles Your Pathology Lab Efficiency

This Embedding Center Cold Plate Doubles Your Pathology Lab Efficiency
Jan 27 , 2026

Say Goodbye to Sectioning Troubles! This Embedding Station Cold Plate Doubles Your Pathology Lab Efficiency


In the workflow of pathological diagnosis, tissue embedding serves as a critical link connecting tissue processing and sectioning. Its quality directly determines the integrity and clarity of subsequent pathological sections, which in turn affects the accuracy of diagnostic results. As a core auxiliary device in this process, the tissue embedding machine cooling plate acts as an "unsung guardian" of pathological laboratories by providing a stable environment for paraffin embedding through precise low-temperature control. It is more than a simple cooling tool; it can also reduce tissue morphological variations through scientific temperature regulation, offering reliable tissue sample carriers for pathologists.


embedding station

I. What is a Tissue Embedding Machine Cooling Plate?

A Tissue Embedding & Cooling System is a professional device used for tissue sample processing in pathological laboratories. It is usually used with embedding machines and paraffin dispensers, with the main functions as follows:

Quickly cool and solidify paraffin containing tissue samples, allowing the tissue blocks to obtain uniform and stable hardness, laying a solid foundation for subsequent sectioning.

Provide a precise low-temperature environment to avoid tissue shape changes caused by temperature fluctuations, ensuring the accuracy of pathological diagnosis.

Take our YSD-300 Tissue Embedding & Cooling System as an example. It integrates modules such as a cooling plate, heating plate, and paraffin storage, realizing integrated operation of sample processing.

embedding center cooling plate



II. Usage Method of Tissue Embedding Machine Cooling Plate

1. Startup Preparation

After connecting the power supply, the device will automatically load the preset temperature parameters. You can also adjust the cooling plate temperature (usually set between -5℃~10℃) on the LCD interface according to the sample type and experimental requirements.

Wait for the device to reach the set temperature to ensure uniform temperature on the cooling plate surface.


embedding center with cooling plate


2. Sample Embedding Operation

Put the dehydrated and paraffin-embedded tissue samples into the embedding frame, and pour melted paraffin.

Quickly place the embedding frame on the cooling plate surface, and the paraffin will solidify rapidly at low temperature.

After the paraffin is completely solidified, the embedded tissue block can be removed for the next sectioning operation.



tissue embedding center


3. Daily Maintenance

Keep the cooling plate surface clean to avoid residual paraffin affecting the cooling effect.

Regularly inspect the device's refrigeration module and temperature sensor to ensure stable operation.


III. YSD-300 Tissue Embedding & Cooling System: Functional Highlights


Item Embedding Center Cooling Plate
Operating ℃
RT -85℃ RT -20℃
Capacity 4L 50 blocks soled in 30 mins
Display LED LED
Size 670*590*445mm 685*380*430mm
Power 1000W 300W


Our YSD-300 System is specially designed for efficient work in pathological laboratories, with the following core advantages:

•  Precise Temperature Control: Adopts a new variable frequency compressor, the cooling plate temperature can be adjusted independently, and it can also be used for rapid tissue freezing to meet diverse sample needs.

•  Intelligent Protection: Multiple overheating protection mechanisms, combined with imported American silicone rubber heating elements, ensure uniform heating, energy saving, and safe and stable operation of the device.

•  Easy Operation: A high-definition LED interface with icons displays the working status, and the dual-switch control design supports finger or foot pedal operation, improving laboratory work efficiency.

Flexible Configuration: Detachable module design simplifies maintenance; the automatic memory function can save preset temperature data, enabling quick startup and operation.


tissue embedding center cooling plate


IV. Choose Us, Choose Professionalism

As an enterprise focusing on the R&D and manufacturing of pathological equipment, we always take "precision, reliability, and efficiency" as the core, providing professional solutions for pathological laboratories around the world. From tissue processing to diagnostic imaging, our equipment accompanies pathologists through every key link, assisting in accurate diagnosis and guarding life and health.

If you are looking for a tissue embedding device with stable performance, easy operation and adaptability to multiple scenarios, the YSD-300 Tissue Embedding & Cooling System will be your ideal choice. Welcome to contact our sales team for detailed product parameters, free sample testing services and customized procurement plans, and let professional equipment escort your pathological diagnosis work.

оставить сообщение